Vue de la page 22
21
1500
MIN.
300
MIN.
300
10
MIN.
400
MIN.
1800
5 - POSITIONING
Technical Dept. - All rights reserved - Reproduction is prohibited
REQUIREMENTS FOR INSTALLATION OF THE PLANT - POSITIONING
The most important thing to do before installing the stove is to choose a suitable place that meets the minimum requirements for
installation.
the minimum clearance in front of the product to allow suitable access for cleaning, maintenance, etc. must be 400 mm;
the minimum permissible distance between the back of the product and a wall must be 10 mm;
the minimum distance between the top of the product and the ceiling must be 600 mm to ensure easy access to the heat exchanger
for the purpose of cleaning and maintenance (e.g. for removing ash);
the minimum clearance between the product and the wall (side) must be 300 mm.